Our DNA: using resources consciously
Our conviction: the best energy is the energy you don’t use at all!
AT: EPS-S
Thanks to the special hydrophobized raw material and the highest degree of fusion, the molded plinth insulation board with special diamond pattern is the optimal solution for the plinth area. Awarded the Austrian Ecolabel.
expanded polystyrene rigid foam, molded, hydrophobized
Plinth insulation, above ground level in the splash zone, external insulation extending into the ground acc. to ÖN B 6400, facade insulation (full thermal insulation), render base board. As a thermal insulation board for areas with higher requirements for the adhesive tensile strength between the board surface and the applied base coat.
0,035 W/(m.K)
≥ 120 kPa (≥ 0.12 N/mm²)
≥ 150 kPa (≥ 0.15 N/mm²)
straight butt edge/without shiplap: 1,000 x 500 mm
in bundles in PE film
| Element thickness mm | Thermal resistance ¹⁾ m²K/W | Thermal transmittance ²⁾ W/m²K |
|---|---|---|
| 20 ³⁾ | 0,55 | 1,39 |
| 30 ³⁾ | 0,85 | 0,98 |
| 40 | 1,15 | 0,76 |
| 50 | 1,45 | 0,62 |
| 60 | 1,75 | 0,52 |
| 80 | 2,30 | 0,40 |
| 100 | 2,90 | 0,33 |
| 120 | 3,50 | 0,27 |
| 140 | 4,10 | 0,23 |
| 160 | 4,65 | 0,21 |
| 180 | 5,25 | 0,18 |
| 200 | 5,85 | 0,17 |
| 220 | 6,45 | 0,15 |
| 240 | 7,00 | 0,14 |
| 260 | 7,60 | 0,13 |
| 280 | 8,20 | 0,12 |
| 300 | 8,75 | 0,11 |
| 350 | 10,25 | 0,10 |
| 400 | 11,70 | 0,08 |
¹⁾ calculated with λD, rounded according to EN 13163
²⁾ calculated with λD, surface heat transfer resistances acc. to ÖN B 8110-2 included
³⁾ Board cut, surface without diamond pattern