Standard-compliant UV testing according to DIN EN ISO 4892-2
A standardized test procedure was used to test the UV resistance of various pipe insulation products. Artificial weathering was carried out using xenon lamps to simulate natural aging caused by sunlight. The test cycle consisted of 102 minutes of dry UV irradiation and 18 minutes of water spray. The UV radiation used was in the wavelength range of 300 to 400 nanometers and thus largely corresponds to the natural solar spectrum.
In general, UV radiation is divided into three ranges:
UVA: 315–400 nm
UVB: 280–315 nm
UVC: 100–280 nm
(is almost completely shielded by the ozone layer and therefore not relevant for the experiment)
Stamatiadis-Smidt & zur Hausen, 1998