Thermal Insulation

Thermal Insulation

More comfort, less energy!

We ensure comfort and well-being inside a house by heating in winter and cooling in summer. Professional thermal insulation measures not only increase living comfort, but also largely determine a building’s energy demand.

 

Mineral or synthetic insulation materials?

Both have their strengths and should be used accordingly. Mineral insulation materials are of natural origin, but compared to synthetic products they require significantly more primary energy to produce. For example, steinothan® insulation boards made of polyurethane (PU) have better thermal conductivity than mineral materials. The result: higher insulation performance, lower insulation thickness. The efficient steinothan® is therefore suitable for components where very slim build-ups are beneficial, such as in pitched roof or flat roof insulation.

 

The more efficient the insulation, the more space

Living space is scarce, especially in cities and metropolitan areas, and every square meter is precious. The external dimensions of a building are dictated by the size of the plot and the development plan. However, by using insulation materials with low thermal conductivity, you can gain living space inside! Because the more efficient the insulation material, the thinner it can be. For sloped roofs, we recommend the most efficient tapered insulation possible in order to save build-up height and weight (on terraces, for example, connection heights are often tight). The EPS and PU tapered boards can also be combined with polyurethane base insulation boards, e.g. steinothan FD with EPS-W 30 plus tapered boards.

 

Beispiel Aufbauhöhen im Warmdach

Especially with pitched roofs, slim build-ups make it possible to gain valuable living space – provided the development plan and room height allow it. 

Beispiel Aufbauhöhen im Steildach

Excerpt from the current OIB Guidelines

The building regulations of the federal states are by and large based on the OIB Guidelines of the Austrian Institute of Construction Engineering. However, where subsidies for the creation of housing or renovation or provisions for the building envelope are concerned, stricter requirements or additional provisions apply in some federal states. In any case, the limits shown in the table must be complied with. Here are the most important requirements from OIB Guideline 6 (abridged excerpt):

Building component U-value (W/m2K) Recommendation for low-energy house (W/m2K) Recommendation for passive house (W/m2K)
WALLS against outside air 0,35 0,20 0,10
WALLS against unheated or unconverted attic spaces 0,35 0,20 0,10
WINDOWS, FRENCH DOORS, GLAZED DOORS, each in residential buildings, against outside air 1) 1,40 0,70 0,70
ROOF WINDOWS against outside air 2) 1,70    
DOORS unglazed, against outside air 3) 1,70    
CEILINGS and ROOF SLOPES, each against outside air and against attic spaces (ventilated or uninsulated) 4) 0,20 0,15 0,10
CEILINGS/FLOORS against unheated parts of the building 4) 0,40 0,20 0,10
FLOORS above outside air (e.g. above passageways, parking decks) 4) 0,20 0,15 0,10
CEILINGS/FLOORS against garages 4) 0,30    
FLOORS in contact with the ground 4) 0,40 0,15 0,10

1) For windows, a standard test size of 1.23m x 1.48m is to be used for verification of the U-value; for French doors and glazed doors, the size 1.46m x 2.16m.

2) For roof windows, a standard test size of 1.23m x 1.48m is to be used for verification of the U-value,

3) For doors, the standard test size of 1.23m x 2.16m is to be used

4) For small areas of ceilings and floors against outside air, the U-value may be up to twice the required value for 2% of the respective area, provided ÖNORM B110-2 (freedom from condensation) is complied with

In addition, special requirements apply to components with wall, floor and ceiling heating:

 

Building component Heating surface to outside air Heating surface – ground or unheated parts of the building
Minimum thermal resistance below surface heating Rt (m2K/W) ≥ 0,40 ≥ 3,5
steinopor® EPS-W 20
λ=0.038 W/(m.K) thickness (mm)
160 140
steinothan® 107
λ=0.023 W/(m.K) thickness (mm)
100  90 (40+50)