Sound Insulation

Both the properties of the building materials and the build-up of the entire construction are decisive for effective sound insulation

Sound Insulation

Sound – causes and types

A building has the task of protecting people from harmful environmental influences. Protection against noise pollution such as road and air traffic noise, noise from neighbors, industry and commerce, among others, is becoming increasingly important. Professional sound insulation in residential construction is a must due to legal requirements. After all, one’s private domain serves as a retreat for relaxation and recovery. But sound insulation also plays a major role in buildings where people spend longer periods – hospitals, offices, hotels.

Pay attention to it as early as the planning stage

To avoid problems and expensive renovations here, the requirements must be taken into account as early as the planning stage. In general, construction engineering distinguishes between two types of sound: 1. airborne sound: sound that propagates through the air – and 2. structure-borne sound: sound that propagates in a solid body and is partly radiated as airborne sound.

What matters in sound insulation?

In roof constructions, what matters first and foremost is airborne sound insulation against outside noise, but also between apartments, in the area where the roof connects to flanking walls and floor slabs. In addition to the acoustic properties of building materials, such as mass, flexibility and sound absorption capacity, the entire component build-up is essential for sound insulation. In pitched roofs with timber constructions, the noise level from outside can be effectively reduced, for example, by applying additional layers on, between and/or under the rafters, as well as by acoustic decoupling.

In constructions with above-rafter insulation in timber construction, the legally required sound insulation can be achieved by using tested PE-laminated PU above-rafter insulation systems, e.g. with the sound insulation element steinothan® 120 silent.

Minimum sound insulation according to OIB Guideline 5: 2015

In Austria, OIB Guideline 5, 2015 or 2011 edition, is anchored in the building codes and valid for the minimum sound insulation of external components. The higher the outside noise level, the higher the requirement for the sound reduction index of the external component. You can find the complete table on structural sound insulation here! Rw=weighted sound reduction index of the opaque external component (roof surface)

Pitched roof tests

For sloping roofs, the extensive Steinbacher portfolio of tested PU system build-ups currently meets the current sound and fire protection regulations best: up to 22 different build-ups are possible – with a sound reduction index of 43dB to 58dB. The product steinothan® 120 silent was developed specifically for sound insulation.

Schallschutz-Messung eines Dachaufbaus mit hoher Lautstärke im Prüfstand im TGM Wien. Geprüft wurden verschiedene Dacheindeckungen der Steinbacher Dämmstoff GmbH