Fire Protection

Certified testing bodies determine the fire resistance of the overall construction at almost 1,000° C

Fire Protection

Reliable fire protection

Building components consist of many different building materials which, depending on the building class, have to meet certain fire protection requirements. Certified testing bodies test the technical properties of the building materials.

Fire class & fire resistance class

Test specimens are subjected to edge or surface flame exposure – this determines the fire class. In a component test, the resistance to fire is determined not for the individual building material, for example the insulation, but for the overall construction, for example the roof in conjunction with all its layers, such as rafters, insulation and boarding or plasterboard. Depending on the construction, components correspond to a certain fire resistance class.

Tested build-ups from Steinbacher

Steinbacher has made it its mission to design tested sound/fire protection build-ups for all variations of exposed roof trusses: 25 tested build-ups that give architects and master timber builders the greatest freedom in planning.

Einsetzen des Dachaufbaus in die Prüfmaschine
Certified testing bodies determine the fire resistance of the overall construction at almost 1,000° C

Fire classes according to EN 13501-1

For a construction product to be classified, all criteria for the corresponding class must be met. Every construction product is clearly declared with regard to its reaction to fire. The reaction to fire is verified by a classification report.

Fire resistance classes according to EN 13501-2

The requirements for the fire resistance of the entire component are set according to the European REI classes of EN 13501-2. The following table defines the abbreviations for classifying fire resistance.

Area of application: description of fire resistance

Abbreviation Meaning derived from
R Load-bearing capacity Résistance
E Integrity Étanchéité
I Thermal insulation Insulation

How are the 5 building classes determined?

Frequently encountered building types are divided into five building classes on the basis of certain criteria such as the number of stories or escape level. The respective test criteria for the corresponding component tests result from the different building classes.

  • For ceilings and roof slopes ≤ 60° above the top story in building classes 2 to 5, the requirements of R 30 and R 60 and/or REI 30 and REI 60 apply explicitly
  • The classification REI 60, for example, denotes a component whose load-bearing capacity, integrity and thermal insulation are maintained for at least 60 minutes in the event of fire.

Fire protection changes in OIB Guideline 2: 2015

With regard to the building classes (GK), the following changes result.

  • GK 1: a maximum of two apartments instead of one as before
  • GK 2: the restriction to five apartments has been removed
  • GK 5 (≤ 6 stories above ground): timber construction is permitted not only in the top two stories but generally, and in stories above ground the provision for components in A2 no longer applies
  • For industrial buildings in timber construction, fire compartments of up to 1,800 m2 are possible without classification, and in classification R 30 up to 3,000 m2 to 10,000 m2, combined with technical fire protection measures
  • As a result, PU above-rafter insulation, for example, can currently be implemented without any problems up to GK 4 with a roof pitch < 20°

(9) In the following cases, EPS, XPS and PUR of class E are also permitted: on roofs with a pitch < 20° or on the top floor ceiling, or on roofs with a pitch ≥ 20°, that are made in A2 and that also meet the fire resistance duration required according to Table 1b with regard to performance characteristics E and I.

(10) EPS, XPS and PUR of class E are also permitted on roofs with a pitch < 20° or on the top floor ceiling if these are made in A2 and the fire resistance duration required according to Table 1b is also met with regard to performance characteristics E and I.

Specific requirements for flat roofs

Fire protection for flat roofs is complex, so fire protection planning should be handled by specialists. For lightweight roofs made of trapezoidal sheet metal decking, as predominantly built in industrial construction today, OIB Guideline 2.1 must generally be complied with. The roof waterproofing system must generally undergo system testing in accordance with the European test method TS 1187 and be classified as BROOF(t1).

Fire protection measures and innovative renovation system

In the event of fire from below, no special measures are necessary for main fire compartment areas of up to 1,800 m2. This is where PU insulation materials such as steinothan®FD score with their low build-up height and can be installed without restrictions. Thanks to our new warm roof renovation system, flat roofs with moisture-laden mineral wool meet the required fire protection even for areas over 1,800 m2. The mineral wool can be retained, which eliminates the cost of disposal. Thanks to the innovative ventilation system, even unforeseen water ingress can be remedied quickly and effectively.